A day in a compliance chamber is expensive, and a product that fails on the first scan can use up that day before any formal result is recorded. Pre-compliance testing exists to stop that happening. It does not replace full compliance testing, but it changes what you take to the lab and how likely you are to leave with a pass. This guide explains what each stage covers, when to use it, and how to prepare.

What pre-compliance testing covers

Pre-compliance is a quick, lower-cost look at how a product behaves before the formal test. It uses the same kinds of measurement as a compliance test, with some compromises on the site and equipment to save time and money. A typical pre-compliance session includes:

  • Conducted emissions on the mains or DC supply, measured with a spectrum analyser or EMI receiver and a line impedance stabilisation network (LISN).
  • Radiated emissions scans with an antenna, often in a screened room or a small chamber, to see which frequencies sit close to the limit line.
  • Near-field probing across the PCB, cables and enclosure seams to find where an emission comes from. Probes locate a source well, but they do not give a figure you can compare with a limit.
  • Spot immunity checks, such as electrostatic discharge or fast transients, where a design is known to be sensitive.

It can be done in-house with your own analyser and probes, or at a lab that offers pre-compliance sessions. A lab session gives you a calibrated set-up and an engineer who has seen the same problems on other products. An in-house set-up suits teams that iterate often and want to check every design change.

What full compliance testing adds

Full compliance testing measures the product against the exact standard, edition and limit class you are claiming, with the test set-up, distances and equipment that standard sets out. Radiated emissions, for example, are measured at a defined distance in a semi-anechoic chamber or on an open area test site. The result is a test report that supports your technical documentation.

Accredited testing goes a step further. In the UK, UKAS accredits test labs to ISO/IEC 17025, and a lab is accredited only for the tests listed on its schedule of accreditation. An accredited report carries the lab's accreditation for those tests, which many customers, approved bodies and overseas markets expect. If the report will leave your company, ask early whether it needs to be accredited, and check that each test is on the lab's UKAS schedule.

Where the regulations fit

For products placed on the market in Great Britain, the Electromagnetic Compatibility Regulations 2016 set two essential requirements: the equipment must not generate disturbance above an acceptable level, and it must have the immunity expected for its intended use. Before placing a product on the market, the manufacturer must carry out a conformity assessment and draw up technical documentation. The regulations provide for internal production control, where the manufacturer carries out the assessment, or type examination by an approved body.

The manufacturer then draws up a declaration of conformity and applies the marking: GOV.UK guidance says either the UKCA or the CE marking can be used in Great Britain, and recognition of CE marking has been extended indefinitely there. Products sold into the EEA still need the CE marking. The technical documentation and declaration must be kept for 10 years. Using designated standards gives a presumption of conformity, which is why the test standard and edition matter so much.

When to use each

  • Early prototype: pre-compliance. Find the big emitters while the layout, filtering and enclosure can still change cheaply.
  • Design freeze: a pre-compliance scan on a production-representative sample, with the cables and power supply the customer will use.
  • Release: full compliance testing to the standards in your declaration, accredited where your customer or market asks for it.
  • After a design change: a pre-compliance check first, then a decision on which compliance tests need repeating.

How a pre-scan saves a failed lab day

A failed compliance test often means a rushed fix in the chamber, a second booking and a delayed launch. A pre-scan a few weeks earlier shows which frequencies are close to the limit and, with near-field probing, where they come from. That gives your engineers time to add filtering, change a cable route or improve a shield before the formal test. Margin matters too: a product that passes a pre-scan by a fraction of a decibel may not pass in a different chamber, so it pays to have a clear margin at pre-compliance before booking full testing.

What to bring to the lab

  • The list of standards, editions and limit classes you are testing to
  • Two or more production-representative samples, with spare fuses and any firmware needed
  • The real cables, power supply and support equipment, and a drawing of the intended set-up
  • A test plan that sets out operating modes, how the product will be monitored, and what counts as a failure during immunity tests
  • Your pre-compliance results, so the lab can start with the frequencies that were close
  • An engineer who knows the design and can make or approve a fix on the day
  • Ferrites, gaskets and filter parts you may want to try if a test is close

Questions to ask a lab

  • Do you offer pre-compliance sessions, and can they lead straight into compliance testing?
  • Which tests are on your UKAS schedule, and which are not?
  • Can you help find the source of an emission on the day, and how is a re-test quoted?
  • Will we get the raw scans as well as the report?

For the wider questions about accreditation, chamber size, uncertainty and report content, our guide on what to check when qualifying a UK EMC test lab goes into each one.

Where to go for more

GOV.UK publishes guidance on the Electromagnetic Compatibility Regulations 2016 for Great Britain and Northern Ireland. UKAS publishes the schedule of accreditation for every accredited lab.

Find EMC test labs on EMC Directory

Compare UK labs offering pre-compliance testing and full compliance testing, or find help with fixes in EMC consultancy and design. Save the labs that fit to your shortlist and send one enquiry to the whole shortlist at once. Details in any directory are what each company states, so confirm them with the lab before booking.

For press enquiries about EMC Directory, contact emc@emcdirectory.co.uk.

Listings related to this article

dB Technology (Cambridge) Limited logo

dB Technology (Cambridge) Limited

Cambridge, Cambridgeshire

dB Technology (Cambridge) holds UKAS accreditation number 9412 to ISO/IEC 17025, plus FCC accreditation (Registration No. 421841), from its Cottenham site, where it runs anechoic and semi-anechoic chambers, a screened room, an open-area test site and an environmental test chamber for EMC and radio-approvals work. Founded in 1988 and incorporated in 1997, the lab tests to CE, UKCA, FCC, ISED and RED requirements across sectors from industrial and medical equipment to household appliances and gaming.

  • Full Compliance Testing
  • Pre-Compliance Testing
  • EMC Consultancy / Troubleshooting
  • Design Review / DFM for EMC
Electromagnetic Testing Services Limited logo

Electromagnetic Testing Services Limited

Stebbing, Essex

Electromagnetic Testing Services holds UKAS accreditation (schedule 4416) with a flexible scope covering commercial and automotive EMC testing, operating from Stebbing, Essex since incorporation in 1992. The lab's work spans commercial, industrial, medical, railway and military product testing, with pre-compliance testing, on-site testing from a mobile unit and EMC consultancy alongside.

  • Full Compliance Testing
  • On-Site Testing
  • EMC Consultancy / Troubleshooting
  • Design Review / DFM for EMC
Kiwa Electrical Compliance (Blackwood) logo

Kiwa Electrical Compliance (Blackwood)

Blackwood, Caerphilly

New

Kiwa Electrical Compliance runs a UKAS accredited EMC and electrical safety laboratory at Pontllanfraith, Blackwood, South Wales, operated by Kiwa Ltd. The site tests IT, multimedia, medical, laboratory, industrial control, domestic appliance and gaming equipment for radiated and conducted emissions, harmonics and flicker, and for immunity to ESD, fast transients, surge, conducted and radiated RF, magnetic fields and voltage dips. Design stage debugging and on site EMC testing for large or high current equipment are also offered.

  • Full Compliance Testing
  • Pre-Compliance Testing
  • On-Site Testing
  • EMC Consultancy / Troubleshooting
Unit 3 Compliance Ltd logo

Unit 3 Compliance Ltd

Bradford, West Yorkshire

Unit 3 Compliance runs an EMC test lab and consultancy from Bradford, West Yorkshire, positioning itself as a lower-cost pre-compliance alternative to larger accredited labs, backed by hands-on troubleshooting and design-for-EMC support. The company advises on CE (EMC Directive and RED), UKCA, FCC and Canadian ICES requirements alongside electrical safety, RoHS and WEEE compliance, and also offers environmental testing such as temperature/humidity and vibration/shock.

  • Full Compliance Testing
  • Pre-Compliance Testing
  • EMC Consultancy / Troubleshooting
  • Design Review / DFM for EMC