Ask two EMC labs to price "EMC testing" for the same product and the quotes can look very different. Usually that is because each lab has assumed a different test plan, not because one is expensive. A lab can only price what it is told, so the way to get quotes you can compare is to send every lab the same, complete brief. This guide explains what drives the cost and what a lab needs from you to quote.
What drives the cost
The test plan. The biggest driver is the list of tests. A product needs emissions tests (radiated and conducted, and on mains-powered products often harmonics and flicker) and immunity tests (such as ESD, radiated and conducted radio-frequency immunity, fast transients, surge and supply dips). Which ones apply, and at what level, is set by the product standard for your equipment. Each test takes set-up and chamber time, so more tests means a higher quote.
The standards and markets. Selling into one market under one product standard is simpler than selling into several. Each extra market can add standards, test levels or a different limit class. Multimedia equipment, for example, is tested to Class A or Class B emission limits under CISPR 32, and the class changes the limit line and can change the set-up. Sector standards for automotive, military, aerospace or rail equipment bring their own methods and are usually priced separately.
Product size and set-up. A small desktop unit fits on a table in a small chamber. A floor-standing cabinet, a machine with long cable runs or a product that needs water, air or a load bank takes longer to set up, may need a larger chamber, and may need testing on site. Support equipment, such as a laptop to exercise the product or a load to drive, adds to the set-up time.
Operating modes and monitoring. A product with one operating mode tests faster than one that must be scanned in several. For immunity tests the lab must watch the product throughout, so a product that needs a camera on its display, a data link monitored or an engineer watching adds time.
Chamber time and how it is charged. Labs price in different ways: a fixed price per test or per standard, a day or half-day rate for the chamber and engineer, or a mix. A fixed price is easier to compare. A day rate suits work where you expect to make changes as you go. Ask which model the quote uses, and what happens if the work runs over.
Accreditation and the report. If the report must be accredited, check that each test is on the lab's UKAS schedule of accreditation. UKAS lists the scope each lab is accredited for, and an accredited report covers only the tests within that scope. Ask whether the report, a declaration of conformity review or technical file support is included or priced separately.
Re-tests. A failure means a fix and a re-test, and a re-test is often where the budget goes. Ask how the lab charges to repeat a test after a design change, and whether you can try a fix in the chamber the same day. A pre-compliance scan before the formal test lowers the chance of paying twice; our guide to pre-compliance or full compliance testing explains when each fits.
What a lab needs to quote
Send the same pack to every lab:
- Product description: what it does, size and weight, and photos.
- Power: mains or DC, voltage, current and number of phases.
- Cables and ports: every cable that connects in use, with its type and length.
- Standards and markets: the product standard(s), editions and limit class, and the markets you plan to sell into. If you are not sure, say so and ask the lab to propose them.
- Operating modes: each mode the product must be tested in, and how it will be monitored.
- Pass criteria: what the product must keep doing during each immunity test.
- Support equipment: what you will bring and what the lab must supply.
- Report: whether it must be accredited, and who will read it (your own file, a customer or an overseas market).
- Samples and timing: how many samples, when they are ready, and the date you need the report.
- Pre-compliance results: if you have them, so the lab can see which tests are close.
Making quotes comparable
When the quotes come back, line them up against the brief:
- Does each quote list the same tests to the same standards and editions?
- Is the price fixed per test, or based on time? If time, how many hours or days are assumed?
- Are set-up, report writing and accreditation included?
- How are re-tests and overruns charged?
- What is the lead time to the first available chamber slot?
- Is pre-compliance offered as a separate session, and can it lead straight into compliance testing?
A quote that is lower because it leaves out a test you need is not a saving. If one lab proposes a different test plan from the others, ask why: it may have spotted a standard the others missed.
Ways to manage the cost
- Test a production-representative sample once, rather than a prototype that will change.
- Group products that share a design into one test plan where the standard allows it, and ask the lab how it would sample them.
- Fix the obvious problems first with a pre-compliance scan. If you test regularly, some companies hire out chambers and equipment for your own engineers to use.
- Book with an engineer who knows the design on site, so fixes can be tried and approved on the day.
Where to go for more
UKAS publishes the schedule of accreditation for every accredited lab, which shows exactly which tests each lab can report under accreditation. GOV.UK publishes guidance on the Electromagnetic Compatibility Regulations 2016. Our guide on what to check when qualifying a UK EMC test lab covers the wider questions to ask before you book.
Get quotes on EMC Directory
Compare UK labs offering full compliance testing and pre-compliance testing. Save the labs that fit to your shortlist and send one enquiry, with the same brief, to the whole shortlist at once, so every quote starts from the same information. Details in any directory are what each company states, so confirm them with the lab before booking.
For press enquiries about EMC Directory, contact emc@emcdirectory.co.uk.
Listings related to this article

Brighton EMC
Brighton, East Sussex
Operating from Paxton's Brighton site, Brighton EMC holds its own UKAS accreditation (schedule 25241) to ISO/IEC 17025, with testing carried out solely at that address. The facility covers emissions and immunity work, including radiated and conducted emissions, ESD, surge, transient/burst and harmonics and flicker, plus pre-compliance scanning, and is used both for Paxton's own products and for hire by outside manufacturers in sectors such as industrial and telecoms equipment.
- Full Compliance Testing
- Pre-Compliance Testing
- EMC Consultancy / Troubleshooting
- Chamber / Equipment Hire
dB Technology (Cambridge) Limited
Cambridge, Cambridgeshire
dB Technology (Cambridge) holds UKAS accreditation number 9412 to ISO/IEC 17025, plus FCC accreditation (Registration No. 421841), from its Cottenham site, where it runs anechoic and semi-anechoic chambers, a screened room, an open-area test site and an environmental test chamber for EMC and radio-approvals work. Founded in 1988 and incorporated in 1997, the lab tests to CE, UKCA, FCC, ISED and RED requirements across sectors from industrial and medical equipment to household appliances and gaming.
- Full Compliance Testing
- Pre-Compliance Testing
- EMC Consultancy / Troubleshooting
- Design Review / DFM for EMC
EMC Hire Ltd
Shefford, Bedfordshire
EMC Hire Ltd operates an EMC test facility in Shefford, Bedfordshire, offering pre-compliance and self-certification testing with or without a test engineer, and on-site EMC testing at customer premises. Tests cover emissions and immunity to commercial, automotive and defence standards using a GTEM cell and a hire fleet of EMC and RF equipment. The company also provides EMC training, RF EMF surveys and problem resolution support, with consultancy through its partner WEMEC Ltd.
- Pre-Compliance Testing
- On-Site Testing
- EMC Consultancy / Troubleshooting
- Chamber / Equipment Hire

GB METECC (UK) Limited
Littlehampton, West Sussex
GB METECC traces back to 2005, when Peter and Sharon Metcalfe founded it as METECC, an EMC consultancy near Burgess Hill; the business was relaunched under the GBE Technology Group in 2024 as GB METECC (UK) Limited, moving into a purpose-built Littlehampton facility. Its 3-metre semi-anechoic chamber covers radiated emissions from 9kHz to 18GHz and radio testing to 25GHz, alongside conducted emissions, immunity, harmonics, flicker, ESD, surge and transient testing, with an Open Area Test Site for larger items.
- Pre-Compliance Testing
- On-Site Testing
- EMC Consultancy / Troubleshooting
- Chamber / Equipment Hire