Get listed Shortlist
Home > Standards > RTCA DO-160 EMC Testing

RTCA DO-160 EMC Testing Companies in the UK

14 companies

3C Test Ltd

Silverstone, Northamptonshire

3C Test has operated as a UKAS-accredited EMC laboratory (number 1204) since before its 1996 incorporation, tracing its roots to 1988, and has been based at Silverstone Technology Park since 2006. The lab became part of Applus+ Laboratories in 2018, and runs 15 EMC facilities across two Silverstone sites, including two full-vehicle EMC chambers and semi-anechoic/reverberation chambers for component testing, covering CE/UKCA, FCC, ISED, VCCI, UNECE R10 vehicle type approval, and Taiwan's VSTD 56-4, for automotive, aerospace/defence, IT and radio-equipment customers. It is also recognised by Ford, GM, Jaguar Land Rover and Stellantis as an approved test lab for automotive components.

  • Full Compliance Testing
  • Pre-Compliance Testing
  • EMC Consultancy / Troubleshooting
  • Global Market Access / Multi-Country Approvals

AQL EMC Limited

Wimborne, Dorset

AQL EMC traces its UKAS accreditation (number 0018) back to 1982, making it the longest continuously accredited EMC test laboratory in the UK; the company itself was formed in 1988 out of an EMC department with roots in MOD ship and submarine testing dating to the 1960s. Based in Wimborne, it tests to RTCA DO-160 (revisions C-F), MIL-STD-461 (revisions C-F), DEF STAN 59-411 and specialist HIRF/attenuation, RS105, HERO, NEMP and RADHAZ testing, either in its own laboratory or on customers' premises. AQL EMC became part of the Eurofins Scientific group in June 2023 and of UL Solutions in October 2026.

  • Full Compliance Testing
  • On-Site Testing
  • EMC Consultancy / Troubleshooting

BAE Systems (Operations) Limited

Rochester, Kent

BAE Systems operates its Faraday Test Centre, a UKAS-accredited EMC facility (laboratory 0047), from its Rochester, Kent site as part of the group's Product Development and Qualification function. The MOD-approved centre runs three large anechoic chambers with interconnecting shielded rooms, testing emissions and susceptibility from 10kHz to 40GHz (pulse-modulated susceptibility up to 2000V/m) to MIL-STD-461, RTCA DO-160, DEF STAN 59-411 and the Eurofighter Typhoon-specific SPE-J-000-E-1000 spec, supporting platforms including Typhoon, F-16, F-22, F-35 and rotary-wing/commercial avionics.

    Compliance Engineering Ltd

    Co Antrim, County Antrim

    New

    Compliance Engineering Ltd, part of Compliance Engineering International (CEI), runs an EMC test site at Randalstown, Co Antrim, accredited to ISO/IEC 17025 by INAB (scope 088T). Its accredited scope there covers emissions, immunity, ESD, fast transients, surge, dips, magnetic field and harmonics testing, including vehicle EMC to CISPR 25 and UN Regulation 10, and railway EMC. Radio and electrical safety testing are accredited at CEI's other site at Dunshaughlin, Co Meath, in the Republic of Ireland, so confirm which site will carry out your testing.

    • Full Compliance Testing
    • Pre-Compliance Testing
    • On-Site Testing
    • EMC Consultancy / Troubleshooting

    Electromagnetic Testing Services Limited

    Stebbing, Essex

    Electromagnetic Testing Services holds UKAS accreditation (schedule 4416) with a flexible scope covering commercial and automotive EMC testing, operating from Stebbing, Essex since incorporation in 1992. The lab's work spans commercial, industrial, medical, railway and military product testing, with pre-compliance testing, on-site testing from a mobile unit and EMC consultancy alongside.

    • Full Compliance Testing
    • On-Site Testing
    • EMC Consultancy / Troubleshooting
    • Design Review / DFM for EMC

    Element Materials Technology Warwick Ltd (Abingdon)

    Abingdon, Oxfordshire

    New

    Element Oxford, formerly the Culham Lightning Studies Unit (established 1972), is a UKAS accredited laboratory on Nuffield Way, Abingdon, testing aerospace and defence equipment for lightning effects and electromagnetic compatibility. Services include indirect lightning testing to RTCA DO-160 Section 22, MIL-STD-461 CS117, AECTP-500 and SPE-J-000-E-1000, surge testing to IEC 61000-4-5 up to 40 kV, and lightning advisory work. The site also tests aerostructures, radomes and fuel system parts for direct lightning strike to DO-160 Section 23, and ground-based lightning protection for wind turbines, telecommunications networks and power distribution. It holds ISO 9001, Cyber Essentials Plus and JOSCAR registration.

    • Full Compliance Testing
    • EMC Consultancy / Troubleshooting

    Element Materials Technology Warwick Ltd (Malvern)

    Malvern, Worcestershire

    Element Materials Technology Warwick operates a UKAS-accredited EMC laboratory (number 0026) from Malvern, Worcestershire (previously TRaC Global), as part of the wider Element global testing network. The site is a Notified Body for CE Marking (including EMC) and holds 7 semi-anechoic chambers, 3 transient chambers and a 20-metre large equipment chamber for automotive and military vehicle testing, serving aerospace, defence, automotive, railway and medical-device customers.

    • Full Compliance Testing

    Element Materials Technology Warwick Ltd (Wimborne)

    Wimborne, Dorset

    New

    Element Wimborne is an EMC test laboratory at Woolsbridge Industrial Park, Three Legged Cross, near Wimborne in Dorset, operated by Element Materials Technology. It tests aerospace, military, automotive, marine, rail and commercial products to standards including MIL-STD-461, DEF STAN 59-411, RTCA DO-160, CISPR 25, ISO 11452, ISO 7637 and UNECE Regulation 10. Facilities include two 3 m CISPR 16 semi-anechoic chambers, a 3 m fully anechoic chamber, reverberation chambers and an indirect lightning laboratory. Radiated emissions are measured from 9 kHz to 18 GHz and radiated susceptibility to 200 V/m. The laboratory holds UKAS ISO/IEC 17025 accreditation.

    • Full Compliance Testing

    Eurofins Electrical & Electronic UK Ltd (Southampton)

    Eastleigh, Hampshire

    New

    The Southampton laboratory of Eurofins Electrical & Electronic UK, part of UL Solutions (formerly Hursley EMC Services), is UKAS-accredited (1574) for EMC and radio testing at Trafalgar Close, Chandler's Ford, Eastleigh. Military and aerospace EMC testing covers DEF STAN 59-411, MIL-STD-461, AECTP 500 and RTCA DO-160, including bulk current injection. Civil testing covers emissions and immunity to CISPR and EN 61000 standards, railway (EN 50121), medical (EN 60601-1-2) and marine (IEC 60945) EMC, radio spurious emissions to ETSI standards, and FCC and ISED scopes. Facilities include semi-anechoic and fully anechoic chambers and dedicated military test chambers.

    • Full Compliance Testing

    Eurofins Electrical & Electronic UK Ltd (York)

    York, North Yorkshire

    Eurofins Electrical & Electronic UK, formerly York EMC Services, has its head office in York and runs UKAS-accredited (1574) EMC, radio and EMF laboratories at Yate near Bristol, Castleford, Grangemouth and Southampton. Its work covers civil, rail and military EMC testing, radio approvals for the UK, EU, US, Canada, Australia, New Zealand and Japan, on-site testing and EMC surveys, EMC consultancy and technical documentation support, and training courses. The company became part of UL Solutions in October 2026.

    • Full Compliance Testing
    • Pre-Compliance Testing
    • On-Site Testing
    • EMC Consultancy / Troubleshooting

    Kiwa Electrical Compliance (Brentwood)

    Brentwood, Essex

    Kiwa Electrical Compliance runs a UKAS-accredited (2360) EMC and radio test laboratory at Arnolds Court, Brentwood, Essex, trading under that name since its rebrand from RN Electronics. Testing covers international schemes including CE, UKCA, FCC, ISED and VCCI, spanning emissions, immunity and pre-compliance work for sectors from IT and medical devices to gaming and automotive accessories. Equipment too large for the lab can be tested on-site. Kiwa's EMC laboratory in Blackwood, South Wales, has its own listing.

    • Full Compliance Testing
    • Pre-Compliance Testing
    • On-Site Testing
    • EMC Consultancy / Troubleshooting

    Peak Electromagnetics Ltd

    Macclesfield, Cheshire

    New

    Peak Electromagnetics is an EMC consultancy in Macclesfield, Cheshire, serving the commercial, defence, aerospace and oil sectors since 2004. Services include EMC design techniques and remedial countermeasures, EMC control and test plans, test procedures to MIL-STD-461/462, DEF STAN 59-411, AECTP 500 and DO-160, test and trials support, measurement uncertainty calculations and CE and UKCA marking compliance. The company also covers lightning and EMP effects, electrostatic discharge protection, radio hazards to electro-explosive devices, non-ionising radiation assessments and third party design reviews. The principal consultant is a Chartered Engineer and UKAS Technical Assessor.

    • EMC Consultancy / Troubleshooting
    • Design Review / DFM for EMC
    • Training Courses
    • Technical File / Certification Support

    QinetiQ Ltd

    Farnborough, Hampshire

    QinetiQ holds UKAS accreditation (laboratory 1936) for RF and E3 (electromagnetic environmental effects) test and evaluation work from its Cody Technology Park site in Farnborough. As one of the UK's largest defence technology companies, its EMC-related test capability sits within a much broader research and evaluation portfolio for military and government customers.

    • Full Compliance Testing
    • On-Site Testing
    • EMC Consultancy / Troubleshooting
    • Design Review / DFM for EMC

    RTCA DO-160 EMC testing in the UK covers the environmental and electromagnetic test procedures for airborne equipment, used across civil and military aerospace. EMC sits in several sections, including power input, voltage spikes, audio frequency and induced signal susceptibility, radio frequency susceptibility and emissions, and lightning induced transients.

    Check which sections and categories your equipment specification calls up, and whether the lab's accreditation covers them. Lightning sections need specialist facilities, so confirm those separately. Some labs also test to EUROCAE ED-14, the European equivalent.

    Use the filters to narrow by accreditation and facility type, then shortlist and send one enquiry to all of them.

    Related pages: Military & Aerospace Testing, MIL-STD-461 EMC Testing.

    Frequently Asked Questions

    Which DO-160 sections are EMC?

    Several, including power input, voltage spike, susceptibility to audio frequency, induced signal and radio frequency, radio frequency emissions, and lightning induced transient susceptibility.

    Do I need every section?

    No. Your equipment specification names the sections and categories that apply.

    Can these labs do lightning testing?

    Some can. Lightning sections need specialist facilities, so check the listing and ask in your enquiry.

    Is DO-160 the same as ED-14?

    They are equivalent documents published by RTCA in the US and EUROCAE in Europe.